HIGH PRESSURE BARREL PUMP FP200
- DP-F-002-000044 // FP200-24 // transmission ratio 24:1
- DP-F-002-000045 // FP200-45 // transmission ratio 45:1
- Safe and uninterrupted conveying of highly viscous and solvent-free media
- Displacement/double stroke: 79 cm³
- Conveying capacity: 4740 cm³/min at 60 double strokes/min
- Transmission ratio: 24:1 (FP200-24); 45:1 (FP200-45)
- Max. container dimensions: 200 l standard barrel
Application
The high pressure barrel pump FP200 is suitable for pumping highly viscous and solvent-free media.
Description
All D+P high pressure barrel pumps are developed in-house and are subject to extremely strict quality control. In-house production ensures optimal and technically perfect adaptation to customer requirements at all times.
Advantages
Our barrel pumps are characterized by high product quality, reliability and long service life. Application of high pressure barrel pumps with follower plate ensures optimal emptying of the barrels. In addition, in contrast to manual emptying, there is no contamination around the barrel.
Technical Data
Pump data
Operating pressure
2–6 bar
Pumping medium
highly viscous and solvent-free media
Displacement/double stroke
79 cm³
Conveying capacity
4740 cm³/min at 60 double strokes/min
Delivery pressure
96 bar (FP200-24); 180 bar (FP200-45)
Transmission ratio
24:1 (FP200-24); 45:1 (FP200-45)
Sound level at 4 bar
73 dB
Compressed air supply
Nominal supply pressure
5 bar
Compressed air quality
dried, filtered, oil-free
Compressed air requirement at 4 bar
556.8 l/min (FP200-24); 991.2 l/min (FP200-45)
Compressed air connection
R 1/4" (coupling plug nominal width 7.2)
Technical dimensions (barrel pump)
Depth x width x height
735 x 1238 x 1786 mm
Height extended
2786 mm
Follower plate (specially adapted to the container)
Diameter follower plate
530 mm
Seal diameter
480 x 45 mm
Material wiper rings
neoprene
Max. container dimensions
200 l standard barrel
Electrical connection indicator light
Connection values
230 V/50 Hz
Environmental conditions
Temperature
10–40 °C
Humidity
50– max. 70 %
Installation conditions
flat industrial floor